NYKR2 Series

    Thermal Overload Relay

    (25-630A)

    Concise Efficient Safe Comprehensive

    PRODUCT OVERVIEW

    NYKR2 series thermal overload relay is a protection device used to protect motors, and its main function is to detect whether the current of the motor exceeds the rated value during operation. Its working principle is trigger the protection based on the heat generated by the current through its control circuit. When there is an overload, it controls the switching devices to protect the line against overload. The thermal relay can effectively protect the motor from damage under abnormal conditions and prolong the service life of the motor. It’s widely used in industry and other fields, it can realize intelligent control and management.

    PRODUCT CHARACTERISTICS

    Simple and reliable

    Thermal relay has simple structure and it utilizes mechanical action based on the principle of physical thermal expansion, which makes them very reliable with a low fault rate.

    Cost effective

    Compared with other types of protective devices, thermal relays have lower cost and are easy to install and maintain, which are suitable for applications at all scales.

    Automatic reset function

    Most thermal relays can be automatically reset when they cool down to normal temperature after triggering the protective device and being powered off, which is conducive to continuous operation and reduces downtime.

    Time delay

    Thermal relays have an inherent feature of time delay that allows them to wait for a motor to overload in a short period of time, which is useful in avoiding unnecessary and frequent tripping.

    Selective protection

    By appropriately setting the thermal relay, it is possible to respond to a specific current, enhancing the overall protection strategy of the system.

    Environmental adaptability

    Thermal relays are not susceptible to external electromagnetic interference, and its performance enables relatively stable operation under various environmental conditions.

    Technical parameters

    Model NYKR2-F25 NYKR2-F36 NYKR2-F95 NYKR2-F150 NYKR2-F220 NYKR2-F630
    Current rating 25 36 95 150 220 630
    Rated insulation voltage 690V 690V 690V 690V 690V 690V
    Phase failure protection
    Manual and automatic reset
    Temperature compensation
    Tripping indication
    Test button
    Stop button
    Installation method Plug-in or free-standing Plug-in or free-standing Plug-in or free-standing Plug-in or free-standing Free-standing Free-standing
    Auxiliary contact 1NO+1NC 1NO+1NC 1NO+1NC 1NO+1NC 1NO+1NC 1NO+1NC
    Auxiliary circuit AC-15 220V Rated currentA 2.72 2.72 2.72 2.72 2.72 2.72
    AC-15 380V Rated currentA 1.58 1.58 1.58 1.58 1.58 1.58
    AC-13 220V Rated currentA 0.2 0.2 0.2 0.2 0.2 0.2
    Selection table

    NYKR2 F25 Additional features
    Product code Casing grade Additional features
    NYKR2:
    Thermal Overload Relay
    F25
    F36
    F95
    F150
    F220
    F630
    Independent mounting base

    Note: NYKR2-F220, NYKR2-F630 are electronic thermal overload relays, the body adopts free-standing mode without mounting base.
    NYKR2-F150 mounting base (free-standing) is independently guide rail mounted with NYKR2-F150 body, NYKR2-F150 mounting base (combined) is mounted in combination with NYKR2-F150 body, and can be directly connected with NYKC2-115, NYKC2-150 AC contactors.

    Technical Parameters


    NYKR2 SeriesThermal Overload Relay

    • Current rating:25

      Rated insulation voltage :690V

      Phase failure protection:Standard configuration

      Manual and automatic reset:Standard configuration

      Temperature compensation:Standard configuration

      Tripping indication:Standard configuration

      Test button:Standard configuration

      Stop button:Standard configuration

      Installation method:Plug-in or free-standing

      Auxiliary contact:1NO+1NC

      Auxiliary circuitAC-15 220V Rated current:2.72A

      Auxiliary circuitAC-15 380V Rated current:1.58A

      Auxiliary circuitDC-13 220V Rated current:0.2A

    • Current rating:36

      Rated insulation voltage :690V

      Phase failure protection:Standard configuration

      Manual and automatic reset:Standard configuration

      Temperature compensation:Standard configuration

      Tripping indication:Standard configuration

      Test button:Standard configuration

      Stop button:Standard configuration

      Installation method:Plug-in or free-standing

      Auxiliary contact:1NO+1NC

      Auxiliary circuitAC-15 220V Rated current:2.72A

      Auxiliary circuitAC-15 380V Rated current:1.58A

      Auxiliary circuitDC-13 220V Rated current:0.2A

    • Current rating:95

      Rated insulation voltage :690V

      Phase failure protection:Standard configuration

      Manual and automatic reset:Standard configuration

      Temperature compensation:Standard configuration

      Tripping indication:Standard configuration

      Test button:Standard configuration

      Stop button:Standard configuration

      Installation method:Plug-in or free-standing

      Auxiliary contact:1NO+1NC

      Auxiliary circuitAC-15 220V Rated current:2.72A

      Auxiliary circuitAC-15 380V Rated current:1.58A

      Auxiliary circuitDC-13 220V Rated current:0.2A

    • Current rating:150

      Rated insulation voltage :690V

      Phase failure protection:Standard configuration

      Manual and automatic reset:Standard configuration

      Temperature compensation:Standard configuration

      Tripping indication:Standard configuration

      Test button:Standard configuration

      Stop button:Standard configuration

      Installation method:Plug-in or free-standing

      Auxiliary contact:1NO+1NC

      Auxiliary circuitAC-15 220V Rated current:2.72A

      Auxiliary circuitAC-15 380V Rated current:1.58A

      Auxiliary circuitDC-13 220V Rated current:0.2A

    • Current rating:220

      Rated insulation voltage :690V

      Phase failure protection:Standard configuration

      Manual and automatic reset:Standard configuration

      Temperature compensation:Standard configuration

      Tripping indication:Standard configuration

      Test button:Standard configuration

      Stop button:Standard configuration

      Installation method:Plug-in or free-standing

      Auxiliary contact:1NO+1NC

      Auxiliary circuitAC-15 220V Rated current:2.72A

      Auxiliary circuitAC-15 380V Rated current:1.58A

      Auxiliary circuitDC-13 220V Rated current:0.2A

    • Current rating:630

      Rated insulation voltage :690V

      Phase failure protection:Standard configuration

      Manual and automatic reset:Standard configuration

      Temperature compensation:Standard configuration

      Tripping indication:Standard configuration

      Test button:Standard configuration

      Stop button:Standard configuration

      Installation method:Plug-in or free-standing

      Auxiliary contact:1NO+1NC

      Auxiliary circuitAC-15 220V Rated current:2.72A

      Auxiliary circuitAC-15 380V Rated current:1.58A

      Auxiliary circuitDC-13 220V Rated current:0.2A

    Selection table


    • Product code :NYKR2:Thermal Overload Relay

      Casing grade:F25、F36、F95、F150、F220、F630

      Additional features:Independent mounting base

    Note: NYKR2-F220, NYKR2-F630 are electronic thermal overload relays, the body adopts free-standing mode without mounting base.
    NYKR2-F150 mounting base (free-standing) is independently guide rail mounted with NYKR2-F150 body, NYKR2-F150 mounting base (combined) is mounted in combination with NYKR2-F150 body, and can be directly connected with NYKC2-115, NYKC2-150 AC contactors.