KLD-AMS Series

    Active Filters

    Ensuring high power quality of industrial and commercial facilities, helping users in various industries to solve the thorny problem of harmonic interference in the power distribution system.

    PRODUCT OVERVIEW

    With the progress of science and technology, more and more power electronic devices and other non-linear loads are applied in companies, such as rectifiers, inverters, UPS, elevators, air conditioners, energy-saving lights, computers, household appliances, etc. These nonlinear loads generate a large amount of harmonic currents that are being injected into the power grid, leading to the voltage waveform distortion. This voltage harmonic pollution can cause serious harm to the grid and all back-end users. In addition, impacting and fluctuating loads, e.g., arc furnace welding equipment, not only generates a large amount of high harmonics in operation, but also causes voltage fluctuations, flickers and three-phase imbalance and other power quality problems, threatening the safe operation of the grid. Harmonics is virtually a kind of interference that “pollutes” the power grid.

    KLD-AMS series active power filters are connected in parallel with the harmonic source. It quickly generates currents that are equal in size and opposite in direction to offset the harmonic currents produced by the harmonic source loads through real-time detection and tracking, thus eliminating harmonics and avoiding distortion of system voltage and current waveforms. The equippment has an adaptive function to compensate for harmonics of varying frequency and size, and quickly responds to the compensation object.

    REAL-TIME DYNAMIC FILTERING RESPONSE

    KLD-AMS series active filters can automatically track the system and control the harmonics according to the actual situation, and can filter out the 2nd to 71st harmonics.

    When the active filter is in normal operation, it can filter the harmonics in the whole range at the same time, and also selectively filter harmonics of various orders, and adjust the filtering rate of random harmonic based on the requirements.

    LAYERED INDEPENDENT AIR DUCT DESIGN

    The module is designed in layered structure and equipped with a dedicated independent cooling system.

    Internal layered design ensures that different functional areas are separated from each other, which is suitable for harsh environments, such as areas filled with dust and conductive particles, saline and alkaline, and humind environment. Each module is equipped with an independent heat dissipation structure, which can quickly transfer and dissipate heat to reduce the operating temperature of the equipment. The noise level of the whole machine is less than or equal to 60dB.

    FAST FOURIER ALGORITHM

    Derived from our experience in harmonic control in various industries, we continuously optimize the fast control algorithm based on FFT.

    DSP decomposes the collected system waveforms through row calculation and identifies the characteristics of the harmonic components that need to be controlled. According to the set parameters and control requirements, it calculates the output current and generates the corresponding pulse width modulation signals to control the inverter IGBT switching devices, so that the main circuit can produce the waveforms as required and achieve the maximum control effect with minimum power consumption.

    THREE-LEVEL TOPOLOGY STRUCTURE

    The whole system adopts three-level topology, providing users with reliable control guarantee!

    • ●   Less ripple current.
    • ●   Less inductor loss.
    • ●   Less switching loss.
    • ●   Higher harmonic filtering efficiency.
    • ●   Higher internal conversion efficiency.
    • ●   Higher switching frequency excitation.
    Technical Parameters

    Input
    Operating voltage 200~690V
    Operating frequency 50/60±10%Hz
    Performance index
    Filtering capacity Up to 97%
    Filtering range 2nd-71st harmonic
    Full response time ≤10ms
    Power factor correction Supported,configurable
    IGBT Frequency 20kHz
    Overload protection Automatic current limiting at 100% of rated output
    Interface module
    Display interface New full-color display, real-time display of system harmonics and harmonic current produced by equipment
    Operation interface LCD intelligent operation unit
    Language Simplified Chinese/English
    Communication interface RS485/RS232
    Environmental operation
    Ambient temperature -10℃~+55℃
    Storage temperature -40℃~+75℃
    Relative humidity Maximum 95%RH (no condensing)
    Altitude ≤1500 meters; between 1500-4000 meters, the power decreases by 1% for every 100m increase
    Selection table

    Model Rated Compensation Current(A) Rated voltage(V) type Cooling method
    Three-phase three-wire system
    KLD-AMS25-3L-400V-HD 25 400 Wall-mounted, with screen Forced air-cooling
    KLD-AMS50-3L-400V-RD 50 400 Rack-mounted, with screen Forced air-cooling
    KLD-AMS100-3L-400V-RC 100 400 Rack-mounted, centralized monitoring and control Forced air-cooling
    KLD-AMS150-3L-400V-RC 150 400 Rack-mounted, centralized monitoring and control Forced air-cooling
    three-phase our-wire system
    KLD-AMS25-4L-400V-HD 25 400 Wall-mounted, with screen Forced air-cooling
    KLD-AMS50-4L-400V-RD 50 400 Rack-mounted, with screen Forced air-cooling
    KLD-AMS100-4L-400V-RC 100 400 Rack-mounted, centralized monitoring and control Forced air-cooling
    KLD-AMS150-4L-400V-RC 150 400 Rack-mounted, centralized monitoring and control Forced air-cooling

    Technical Parameters


    • Input

      Operating voltage:200~690V

      Operating frequency:50/60±10%Hz

      Performance indicators

      Filtering capacity:Up to97%

      Filtering range:2nd-71st harmonic

      Full response time:≤10ms

      Power factor correction:Supported,configurable

      IGBT Frequency:20kHz

      Overload protection:Automatic current limiting at 100% of rated output

      Interface module

      Display interface:New full-color display, real-time display of system harmonics and harmonic current produced by equipment

      Operation interface:LCD intelligent operation unit

      Language:Simplified Chinese/English

      Communication interface:RS485/RS232

      Environmental operation

      Ambient temperature:-10℃~+55℃

      Storage temperature:-40℃~+75℃

      Relative humidity:Maximum 95%RH (no condensing)

      Altitude:≤1500 meters; between 1500-4000 meters, the power decreases by 1% for every 100m increase

    Selection table

    Three-phase three-wire system

    • Rated Compensation Current(A):25

      Rated voltage(V):400

      Type:Wall-mounted, with screen

      Cooling method:Forced air-cooling

    • Rated Compensation Current(A):50

      Rated voltage(V):400

      Type:Rack-mounted, with screen

      Cooling method:Forced air-cooling

    • Rated Compensation Current(A):100

      Rated voltage(V):400

      Type:Rack-mounted, centralized monitoring and control

      Cooling method:Forced air-cooling

    • Rated Compensation Current(A):150

      Rated voltage(V):400

      Type:Rack-mounted, centralized monitoring and control

      Cooling method:Forced air-cooling

    Three-phase our-wire system

    • Rated Compensation Current(A):25

      Rated voltage(V):400

      Type:Wall-mounted, with screen

      Cooling method:Forced air-cooling

    • Rated Compensation Current(A):50

      Rated voltage(V):400

      Type:Rack-mounted, with screen

      Cooling method:Forced air-cooling

    • Rated Compensation Current(A):100

      Rated voltage(V):400

      Type:Rack-mounted, centralized monitoring and control

      Cooling method:Forced air-cooling

    • Rated Compensation Current(A):150

      Rated voltage(V):400

      Type:Rack-mounted, centralized monitoring and control

      Cooling method:Forced air-cooling

    page top