KLD-FD Series

    Low-voltage Filter Reactor

    Filter reactors can effectively protect the capacitors, reduce overload caused by harmonics during compensation, and avoid the possibility of resonance with grid inductance.

    PRODUCT OVERVIEW

    If there are electricity loads generated by inverters, rectifiers and other devices that produce harmonics in the power grid, the capacitor cabinet needs to be equipped with filter reactors. Low-voltage filter reactors in series with capacitors can withstand the losses generated by fundamental and harmonic currents, and will not exceed the temperature range of the insulating material in normal conditions.

    KLD-FD series low-voltage filter reactors have high accuracy and linearity to withstand the switching of capacitors and will not cause saturation because of large grid harmonic distortions. Its iron core reactors designed with leakage prevention function have lower losses and noise levels.

    Low-voltage filter reactor and capacitor in series consist of low-voltage reactive power compensation device, which will provide reactive power compensation to the grid system, improve power factor, reduce losses from the line and transformer and play a vital role in supporting the voltage. It also suppresses the amplification of harmonic current, eliminates the hidden hazards of resonance, and fully protects the operation safety and service life of capacitors.

    RELIABLE OPERATION PERFORMANCE

    Excellent electrical characteristics due to high quality materials and precise mounting.

    In the production process, products are impregnated and solidified under vacuum to avoid the impact of water molecule on the performance and service life of reactor. Each reactor is equipped with an over-temperature protection point for the customer to ensure that the linkage switch can be quickly and reliably cut off under abnormal conditions.

    HIGH LINEARITY AND SHORT-TIME CURRENT

    Linearity and short-time current are important parameters, 2.0ln linearity and 50 times rated short-time current.

    The magnetic field is produced when the coil flows through the current and Reactance coefficient as the current increases. When it reaches a certain level and can not continue to enhance, i.e., "magnetic saturation", the inductance value experience a parabolic decline from a fixed value. KLD-FD series reactors will not be magnetically saturated when passing 2.01n.

    Technical Parameters

    Rated voltage 230~800V,50/60Hz
    Output power 5~100kvar
    Reactance 7%, 14% or other reactance
    Overload capacity 1.8In
    Maximum voltage 1.1Un
    Linearity 2.0In
    Cooling method Natural cooling
    Insulation between layers Nomex high-quality insulating paper
    Impregnation method Polyester resin, class H
    Insulation level Winding-iron core 3kV
    Over-temperature protection 120°C normally closed contact
    Parameter tolerance ±3%
    Altitude Conventional 2,000 meters (higher altitude can be customized)
    Ambient temperature -40℃~+45℃(up to +55℃)
    Technical Standard Complies with GB1094、VDE0550/0532、IEC76
    Selection table

    Model Capacity(kvar) Reactance Coefficient Outlet mode Temperature monitoring
    Single-phase
    KLD-FD7-5-1-230V 5 7% Side outlet Provided
    KLD-FD7-10-1-230V 10 7% Side outlet Provided
    KLD-FD7-15-1-230V 15 7% Side outlet Provided
    KLD-FD14-5-1-230V 5 14% Side outlet Provided
    KLD-FD14-10-1-230V 10 14% Side outlet Provided
    KLD-FD14-15-1-230V 15 14% Side outlet Provided
    Three-phase
    KLD-FD7-12.5-400V 12.5 7% Side outlet Provided
    KLD-FD7-15-400V 15 7% Side outlet Provided
    KLD-FD7-20-400V 20 7% Side outlet Provided
    KLD-FD7-25-400V 25 7% Side outlet Provided
    KLD-FD7-30-400V 30 7% Side outlet Provided
    KLD-FD7-40-400V 40 7% Side outlet Provided
    KLD-FD7-50-400V 50 7% Side outlet Provided
    KLD-FD7-60-400V 60 7% Side outlet Provided
    KLD-FD14-12.5-400V 12.5 14% Side outlet Provided
    KLD-FD14-15-400V 15 14% Side outlet Provided
    KLD-FD14-20-400V 20 14% Side outlet Provided
    KLD-FD14-25-400V 25 14% Side outlet Provided
    KLD-FD14-30-400V 30 14% Side outlet Provided
    KLD-FD14-40-400V 40 14% Side outlet Provided
    KLD-FD14-50-400V 50 14% Side outlet Provided
    KLD-FD14-60-400V 60 14% Side outlet Provided

    Technical Parameters


    • Rated voltage:230~800V,50/60Hz

      Output power:5~100kvar

      Reactance: 7%, 14% or other reactance

      Overload capacity:1.8In

      Maximum voltage:1.1Un

      Linearity:2.0In

      Cooling method:Natural cooling

      Insulation between layers:Nomex high-quality insulating paper

      Impregnation method:Polyester resin, class H

      Insulation level:Winding-iron core 3kV

      Over-temperature protection:120°C normally closed contact

      Parameter tolerance:±3%

      Altitude:Conventional 2,000 meters (customized for higher altitude)

      Ambient temperature:-40℃~+45℃(up to +55℃)

      Technical standards:Complies with GB1094、VDE0550/0532、IEC76

    Selection table


    Single-phase

    • Capacity(kvar):5

      Reactance Coefficient:7%

      Outlet mode:Side outlet

      Temperature monitoring:Provided

    • Capacity(kvar):10

      Reactance Coefficient:7%

      Outlet mode:Side outlet

      Temperature monitoring:Provided

    • Capacity(kvar):15

      Reactance Coefficient:7%

      Outlet mode:Side outlet

      Temperature monitoring:Provided

    • Capacity(kvar):5

      Reactance Coefficient:14%

      Outlet mode:Side outlet

      Temperature monitoring:Provided

    • Capacity(kvar):10

      Reactance Coefficient:14%

      Outlet mode:Side outlet

      Temperature monitoring:Provided

    • Capacity(kvar):15

      Reactance Coefficient:14%

      Outlet mode:Side outlet

      Temperature monitoring:Provided

    Three-phase

    • Capacity(kvar):12.5

      Reactance Coefficient:7%

      Outlet mode:Side outlet

      Temperature monitoring:Provided

    • Capacity(kvar):15

      Reactance Coefficient:7%

      Outlet mode:Side outlet

      Temperature monitoring:Provided

    • Capacity(kvar):20

      Reactance Coefficient:7%

      Outlet mode:Side outlet

      Temperature monitoring:Provided

    • Capacity(kvar):25

      Reactance Coefficient:7%

      Outlet mode:Side outlet

      Temperature monitoring:Provided

    • Capacity(kvar):30

      Reactance Coefficient:7%

      Outlet mode:Side outlet

      Temperature monitoring:Provided

    • Capacity(kvar):40

      Reactance Coefficient:7%

      Outlet mode:Side outlet

      Temperature monitoring:Provided

    • Capacity(kvar):50

      Reactance Coefficient:7%

      Outlet mode:Side outlet

      Temperature monitoring:Provided

    • Capacity(kvar):60

      Reactance Coefficient:7%

      Outlet mode:Side outlet

      Temperature monitoring:Provided

    • Capacity(kvar):12.5

      Reactance Coefficient:14%

      Outlet mode:Side outlet

      Temperature monitoring:Provided

    • Capacity(kvar):15

      Reactance Coefficient:14%

      Outlet mode:Side outlet

      Temperature monitoring:Provided

    • Capacity(kvar):20

      Reactance Coefficient:14%

      Outlet mode:Side outlet

      Temperature monitoring:Provided

    • Capacity(kvar):25

      Reactance Coefficient:14%

      Outlet mode:Side outlet

      Temperature monitoring:Provided

    • Capacity(kvar):30

      Reactance Coefficient:14%

      Outlet mode:Side outlet

      Temperature monitoring:Provided

    • Capacity(kvar):40

      Reactance Coefficient:14%

      Outlet mode:Side outlet

      Temperature monitoring:Provided

    • Capacity(kvar):50

      Reactance Coefficient:14%

      Outlet mode:Side outlet

      Temperature monitoring:Provided

    • Capacity(kvar):60

      Reactance Coefficient:14%

      Outlet mode:Side outlet

      Temperature monitoring:Provided