KLD-MK Series

    Low-voltage Power Capacitor

    An innovative inflatable self-healing explosion-proof capacitor that adopts both safe and environmental protection technologies, with lower losses and smaller size.

    PRODUCT OVERVIEW

    KLD series low-voltage capacitor is characterized by an innovative cylindrical explosion-proof function that uses gradient metallized polypropylene film technology to ensure windings with ideal self-healing characteristics. We use gas instead of conventional dielectrics such as oil and resin, and dry technology to meet the higher requirement for environmental protection and safety as well as small size.

    The operating stability of the capacitors is ensured by long-term vacuum drying technology. Unique vacuum evaporation and corrugated cutting technology and optimized winding sequencing make our capacitors not only have outstanding capacity-to-volume ratio, but also have strong capability to withstand AC, effective and peak current impacts. Portable assembly method and good heat dissipation ensure a greater degree of installation space saving while removing harmonic hazards and correcting power factor.

    The technical design, testing and use of the product are in compliance with GB12747.1/GB12747.2/IEC60831 standards, with CE certificate and ROHS environmental certificate.

    EXCELLENT SELF-HEALING PERFORMANCE

    Vacuum evaporation process with gradient metal layers features balances between current-carrying capacity and self-healing properties.

    Capacitor winding dielectric is made of gradient metallized polypropylene film. It evaporates metal particles through partial breakdown and re-form the insulating area, so that the capacitor isolates the fault point on its own and continues to work normally, achieving the self-healing function. At the same time, the capacity loss due to breakdown is negligible and does not affect the normal operation of the capacitor.

    EDGE THICKENING AND CORRUGATED CUTTING TECHNOLOGY

    Windings with edge thickening and corrugated cutting technology enhance thereliable connection between the gold-sprayed particles and the metallization layer.

    Capacitor adopts film edge thickening reinforcement technology, which can enhance the reliable connection between the gold-sprayed surface and the electrode. The internal film The internal film uses both corrugated and smooth cutting methods, which maximizes the effective surface between the component and the metallization layer and improves surge current suppression capability.

    SPECIAL GOLD-SPRAYED PROCESS

    Outstanding surge resistance ensures low inductance connection between terminals and windings.

    Fine zinc powder particles are injected into into the end face of the component by high-speed gold-sprayed technology and formed into a delicate gold-sprayed surface, on which you can lead out the electrode. In the whole process, each winding group should strictly control the thickness and flatness of the gold-sprayed layer to achieve the effect of low loss, stable performance and long service life.

    MORE SAFETY CONSIDERATIONS

    Consideration of user-friendly safety measures to prevent accidents and contacts

    According to GB12747/IEC60831 standards, each capacitor has strictly passed the factory routine test: each three-phase capacitor terminal is equipped with an end cover that can prevent your fingers contact with the live component by accident. Also, it is combined with a discharging compartment, which can protec the personal safety of the personnel at the site.

    HIGHLY EFFICIENT OVERPRESSURE
    ISOLATION TECHNOLOGY

    "Pressure-relief technology" makes the capacitor safer

    KLD-MK series capacitors have a cylindrical aluminum can case with a "pressure-relief structure" inside. Pressure can be relieved by pushing up the top of the capacitor. At the same time, the internal metal wires are pulled off, effectively blocking current flow and isolating the capacitor.

    Technical Parameters

    Rated voltage 230~1000V,50/60Hz
    Overvoltage 1.1Un(long term), 1.15Un(30min), 13Un(5min)
    Overcurrent 2.0In
    Surge current 500In
    Capacitance tolerance ±5%
    Dielectric High-quality polypropylene film
    Perfusion material Inert insulating material gas, nitrogen gas
    Dielectric loss ≤0.1W/kvar
    Safety features Dry technology, overvoltage isolator, self-healing
    Discharge time Discharge to below 50V in 50s with discharge resistance
    External structure Cylindrical aluminum metal shell with safety bolts at the bottom
    Ambient temperature -40/D; max. temperature +55°C, average daily max. +45°C, average annual max. +35°C, min. -40℃
    Cooling method Natural or forced cooling
    Installation position Anywhere, bottom bolt grounding
    Relative humidity ≤95%
    Altitude Conventional 2,000 meters (customized for higher altitude)
    Protection degree IP20, Indoor assembly (installed with the cover that meets IPS4)
    Service life >200000h
    Technical Standards Complies with GB12747、IEC60831、VDE0560-46/47
    Selection table

    Model Capacity(kvar) Loss(W/kvar) Designed service life(h)
    Single-phase
    KLD-MK-5-1-280V 5 ≤0.1 200,000
    KLD-MK-10-1-280V 10 ≤0.1 200,000
    KLD-MK-15-1-280V 15 ≤0.1 200,000
    KLD-MK-5-1-300V 5 ≤0.1 200,000
    KLD-MK-10-1-300V 10 ≤0.1 200,000
    KLD-MK-15-1-300V 15 ≤0.1 200,000
    Three-phase
    KLD-MK-12.5-480V 12.5 ≤0.1 200,000
    KLD-MK-15-480V 15 ≤0.1 200,000
    KLD-MK-20-480V 20 ≤0.1 200,000
    KLD-MK-25-480V 25 ≤0.1 200,000
    KLD-MK-30-480V 30 ≤0.1 200,000
    KLD-MK-12.5-525V 12.5 ≤0.1 200,000
    KLD-MK-15-525V 15 ≤0.1 200,000
    KLD-MK-20-525V 20 ≤0.1 200,000
    KLD-MK-25-525V 25 ≤0.1 200,000
    KLD-MK-30-525V 30 ≤0.1 200,000

    Technical Parameters


    • Rated voltage:230~1000V,50/60Hz

      Overvoltage:1.1Un(long term), 1.15Un(30min), 13Un(5min)

      Overcurrent:2.0In

      Surge current:500In

      Capacitance tolerance:±5%

      Dielectric:High-quality polypropylene film

      Perfusion material:Inert insulating material gas, nitrogen gas

      Dielectric loss:≤0.1W/kvar

      Safety features:Dry technology, overvoltage isolator, self-healing

      Discharge time:Discharge to below 50V in 50s with discharge resistance

      External structure:Cylindrical aluminum metal shell with safety bolts at the bottom

      Ambient temperature:-40/D; max. temperature +55°C, average daily max. +45°C, average annual max. +35°C, min. -40℃

      Cooling method:Natural or forced cooling

      Installation position:Anywhere, bottom bolt grounding

      Relative humidity:≤95%

      Altitude:Conventional 2,000 meters (customized for higher altitude)

      Protection degree:IP20, Indoor assembly (installed with the cover that meets IPS4)

      Service life:>200000h

      Technical standards:Complies with GB12747、IEC60831、VDE0560-46/47

    Selection table


    Single-phase

    • Capacity(kvar):5

      Loss(W/kvar):≤0.1

      Designed service life(h):200,000

    • Capacity(kvar):10

      Loss(W/kvar):≤0.1

      Designed service life(h):200,000

    • Capacity(kvar):15

      Loss(W/kvar):≤0.1

      Designed service life(h):200,000

    • Capacity(kvar):5

      Loss(W/kvar):≤0.1

      Designed service life(h):200,000

    • Capacity(kvar):10

      Loss(W/kvar):≤0.1

      Designed service life(h):200,000

    • Capacity(kvar):15

      Loss(W/kvar):≤0.1

      Designed service life(h):200,000

    Three-phase

    • Capacity(kvar):12.5

      Loss(W/kvar):≤0.1

      Designed service life(h):200,000

    • Capacity(kvar):15

      Loss(W/kvar):≤0.1

      Designed service life(h):200,000

    • Capacity(kvar):20

      Loss(W/kvar):≤0.1

      Designed service life(h):200,000

    • Capacity(kvar):25

      Loss(W/kvar):≤0.1

      Designed service life(h):200,000

    • Capacity(kvar):30

      Loss(W/kvar):≤0.1

      Designed service life(h):200,000

    • Capacity(kvar):12.5

      Loss(W/kvar):≤0.1

      Designed service life(h):200,000

    • Capacity(kvar):15

      Loss(W/kvar):≤0.1

      Designed service life(h):200,000

    • Capacity(kvar):20

      Loss(W/kvar):≤0.1

      Designed service life(h):200,000

    • Capacity(kvar):25

      Loss(W/kvar):≤0.1

      Designed service life(h):200,000

    • Capacity(kvar):30

      Loss(W/kvar):≤0.1

      Designed service life(h):200,000

    page top